Treatment of Cognitive Deficits in Multiple Sclerosis With High-Definition Transcranial Direct Current Stimulation
Sponsor: The University of Texas at Dallas • ClinicalTrials.gov ID: NCT05958381
Recruiting for Similar Conditions?
Sponsors are looking for patients like you. See if you qualify for compensated research studies.
Check Eligibility →Description
The purpose of the study is to test whether low level electric stimulation, called transcranial Direct Current Stimulation (tDCS), on the part of the brain (i.e., presupplementary motor area) thought to aid in memory will improve verbal retrieval in multiple sclerosis patients. The primary outcome measures are neuropsychological assessments of verbal retrieval, and the secondary measures are neuropsychological assessments of other cognitive abilities and electroencephalography (EEG) measures. Additionally, the study will examine the degree to which baseline assessments of cognition and concussion history predict responses to treatment over time, both on assessments administered within the intervention period and at follow-up.
Interventions
-
Transcranial Direct Current Stimulation
(Device)
Transcranial direct current stimulation will be delivered via a Neuroelectrics Starstim tES. Stimulation will consist of 1 milliamp stimulation, with anodal stimulation delivered at electrode Fz (International 10/10 System for electroencephalography electrode placement) and electrodes F7, FP1, FP2, and F8 as returns. All electrodes are 1 cm diameter Ag/AgCl electrodes and make contact with the scalp via connective gel. Stimulation will linearly ramp up from 0 milliamps to 1 milliamp over 60 seconds, then remain at 1 milliamp of stimulation over 20 minutes, and finally ramping down at to 0 milliamps over 60 seconds.
-
Sham transcranial direct current stimulation
(Device)
Sham transcranial direct current stimulation will be delivered via a Neuroelectrics Starstim tES. The sham setup will consist of electrodes placed at Fz, F7, FP1, FP2, and F8 (International 10/10 System for electroencephalography electrode placement) . All electrodes are 1 cm diameter Ag/AgCl electrodes and make contact with the scalp via connective gel. Stimulation will linearly ramp up from 0 milliamps to 1 milliamp over 60 seconds, ramp down to 0 milliamps over 60 seconds and then be left off for 20 minutes.
Eligibility criteria
Conditions
Locations
- The University of Texas at Dallas — Richardson, Texas, United States